Brick tile folding machine "calibration method" - Huaqiang Electronic Network

Single chip microcomputer STM32L151CCU6
Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
RF cable can be customized for other specifications
Mobile phone crystal 3.2*2.5mm 3225 26M (26.000MHZ)

Brick folding machine

Structure introduction

The main components of the machine, hydraulic control, force measurement and display.

Vertical

Two

The column structure, the main structure adopts the welded structure and is effectively treated to ensure the rigidity of the whole machine. Hydraulic cylinder placed

Bottom plate

On, when the piston is working out

After giving

Specimen

put pressure on

, test space (width X length):

420

x

550

Mm. Indenter with high quality

Carbon steel

(HRC 45 ~ 50) to ensure its service life. Adopt brand

Oil delivery and return valve

Drive the hydraulic cylinder for the entire test

data

display

Peak planting

And test results

automatic

Print, load speed

Manual control

, can control the loading rate, the holding time, and the cyclic pressure;

Local

Have

Specimen

Break recognition ability. To complete the pair

tile

of

damage

Detection

.

3. Refer to the instrument manual for details of the force measurement and display operation.

Brick folding machine

installation

1. When the test machine is hoisted, use a sling to hang on both sides of the beam, or hang it on the two rings on the top.

2. The test machine is installed on a stable foundation 20 cm above the ground. Four M16 anchor bolts should be embedded.

3. When installing the test machine, measure the plane of the lower pressure plate with a frame level of 1/1000, so that it is in a horizontal state. When adjusting, use the horn (the horn pad is under the nut under the column) and then fasten the test machine to the foundation. on.

Brick folding machine

Operational guidance

1. Add 46# anti-wear hydraulic oil to the fuel filler port of the fuel tank to a distance of 5 cm from the upper surface of the fuel tank.

2. Turn on the power to start the motor (380V 50Hz).

3, put the test piece, with a good block.

4. Tighten the return valve and release the delivery valve. Slowly pressurize and control the speed during the pressurization to prevent overspeed.

5. After the test is finished, loosen the oil return valve (preferably rotate more than two turns), close the oil supply valve, so that the piston will slowly retract (when the piston returns to the original position, stop the machine for the next test), stop the test machine The operation.

6. The safety valve has been debugged at the factory, and do not adjust the safety valve during the experimental operation.

7. The instrument manual describes the operation process of the instrument and is used together.

Brick folding machine

maintenance

1. The test machine is installed at a clean and dry temperature with no vibration around, and no corrosive gas affects the environment.

2. The test machine should be kept clean to keep the moving parts lubricated and prevent rust.

3. Hydraulic oil uses 46# anti-wear hydraulic oil.

4. The hydraulic oil level of the test machine is within 5 cm from the upper surface of the fuel tank. There is a ruler on the test engine cylinder, and the operator can check it regularly.

Brick folding machine

Calibration of test machine

1. The test machine is calibrated once a year.

2. The calibration of the testing machine should be carried out under the following conditions:

a) Room temperature is carried out in the range of 20 ± 10 °C.

b) Relative humidity ≤ 80%.

c) There is no vibration in the surrounding environment.

d) The power supply voltage fluctuation is less than ±10% of the rated voltage.

3. Preheat the instrument for 30 minutes after the power is turned on, and adjust the zero according to the instrument manual.

4. Start the motor and repeat the calibration after three times of loading to the maximum load.

5. The test machine only performs the relative error of the process indication value and the relative variability calibration. The calibration result should reach:

Relative error of indication value ≤±1%

Relative variability of indication value ≤ ± 1%

Brick folding machine configuration

1,

Brick folding

Test machine host 1 (including:

Main Frame,

Cylinder piston,

2

Rigid spacer, force sensor

,

Manual speed control valve)


2. Control one oil source (including:

Controller,

Motor oil pump, oil filter

,

Some tubing)


3, instruction manual,

Certificate of authenticity.