XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable

Model NO.: YJV YJY YJV22 etc.
Warranty: 12 Months
Trademark: GDYG
Transport Package: Wooden Reel, Steel Reel
Specification: 0.5-630 mm2
Origin: Guangdong, China
Model NO.: YJV YJY YJV22 etc.
Warranty: 12 Months
Trademark: GDYG
Transport Package: Wooden Reel, Steel Reel
Specification: 0.5-630 mm2
Origin: Guangdong, China

Basic Information           
Material Shape: Round Wire
Range of Application: Power Grid and All Industry  
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG 
Specification: 0.5mm2 - 630mm2          
Supply Record: America, Australia, African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
Application: Power Grid, Transmission Line, Construction, Railway Transportation, Chemical Plant, Telecom , Oil Industry, Equipment Manufacture, Instrument Industry etc..
Voltage: 35KV, 10KV, 0.6/1KV, 450/750V, 300/500V
Current: AC & DC
Insulation Material: XLPE, PVC
Sheath Material: XLPE, PVC etc.
Material Shape: Round wire



Contruction Sketch
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable
 1. Counductor 
 2. Inner semi-conducting screen
 3. Insulation
 4. Outer semi-conducting screen
 5. Metallic screen
 6. Outer sheath 
 7. Wrapping tape 
 8. Inner sheath 
 9. Steel belt armor
 10. Filler 



Application
It applies to the transmission and distribution lines with rated voltage from 3.6/6kv to 26/35kv, while flame retardant Power Cable is used in the places with special demands of flame retardant property.

U0--rated power frequency voltage between conductors and shield or metallic sheath used for Cable designed.
U--rated power frequency voltage between conductors used for cable designed.
Um--max equipment voltage(max system voltage of the equipment in service).


Characteristics
1.Maximum conductor temperature under normal operation is 90ºC.
2.Maximum conductor temperature under short circuit (max duration is not more than 5s) is nor more than 250ºC.
3.Installation ambient temperature is nor less than 0ºC.
4.Minimum installation bending radius are not less than the following specified values:
  Single core non-armored cable: 20D
  Single core armored cable: 15D
  3 cores non-armored cable: 15D
  3 cores armored cable: 12D
  (Note: D-outer diameter of cable)



Technical Parameters
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Our company
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Workshop
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Certificates
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable
Basic Information           
Material Shape: Round Wire
Range of Application: Power Grid and All Industry  
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG 
Specification: 0.5mm2 - 630mm2          
Supply Record: America, Australia, African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
Application: Power Grid, Transmission Line, Construction, Railway Transportation, Chemical Plant, Telecom , Oil Industry, Equipment Manufacture, Instrument Industry etc..
Voltage: 35KV, 10KV, 0.6/1KV, 450/750V, 300/500V
Current: AC & DC
Insulation Material: XLPE, PVC
Sheath Material: XLPE, PVC etc.
Material Shape: Round wire



Contruction Sketch
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable
 1. Counductor 
 2. Inner semi-conducting screen
 3. Insulation
 4. Outer semi-conducting screen
 5. Metallic screen
 6. Outer sheath 
 7. Wrapping tape 
 8. Inner sheath 
 9. Steel belt armor
 10. Filler 



Application
It applies to the transmission and distribution lines with rated voltage from 3.6/6kv to 26/35kv, while flame retardant power cable is used in the places with special demands of flame retardant property.

U0--rated power frequency voltage between conductors and shield or metallic sheath used for cable designed.
U--rated power frequency voltage between conductors used for cable designed.
Um--max equipment voltage(max system voltage of the equipment in service).


Characteristics
1.Maximum conductor temperature under normal operation is 90ºC.
2.Maximum conductor temperature under short circuit (max duration is not more than 5s) is nor more than 250ºC.
3.Installation ambient temperature is nor less than 0ºC.
4.Minimum installation bending radius are not less than the following specified values:
  Single core non-armored cable: 20D
  Single core armored cable: 15D
  3 cores non-armored cable: 15D
  3 cores armored cable: 12D
  (Note: D-outer diameter of cable)



Technical Parameters
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Our company
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Workshop
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


Certificates
XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable


XLPE/PVC Insulated Copper/Al Rated Voltage Power Cable 3.6/6kv-26/35kv, Medium Voltage Electric Cable

Insulated Male Disconnectors

Disconnectors,Push Button Switch,Isolation Switch,Membrane Switch

Insulated Terminal Ends Co., Lt d , http://www.nbterminal.com